• Home
  • Our Past Work
    • Industrial Waste
    • PFAS Detection in Water
    • Biosolids & Sewage Sludge
    • Municipal & Wastewater
    • Biological Recovery
    • AI and Cyber Security
  • Training Books
  • Certification Courses
    • Wastewater Treatment
    • Biosolids Land Applier
  • Contact Us
  • More
    • Home
    • Our Past Work
      • Industrial Waste
      • PFAS Detection in Water
      • Biosolids & Sewage Sludge
      • Municipal & Wastewater
      • Biological Recovery
      • AI and Cyber Security
    • Training Books
    • Certification Courses
      • Wastewater Treatment
      • Biosolids Land Applier
    • Contact Us
  • Home
  • Our Past Work
    • Industrial Waste
    • PFAS Detection in Water
    • Biosolids & Sewage Sludge
    • Municipal & Wastewater
    • Biological Recovery
    • AI and Cyber Security
  • Training Books
  • Certification Courses
    • Wastewater Treatment
    • Biosolids Land Applier
  • Contact Us
Cache Environmental Laboratories

BIOSOLIDS LAND APPLIER CERTIFICATION TRAINING: Online Course

Learn More Through Udemy

You can take our "Biosolids Land Applier Certification" course through Udemy. They include in-depth video lecture, quizzes, and practice tests. You can gain access to these course by clicking on the image or the link below!

Click Here
Biosolids Land Applier Certification Workbook cover

Supplementary Material:

To get the most out of our online course, we highly recommend you also purchase our "Biosolids Land Applier Certification" workbook. It includes all of the slides used in the lectures and gives you room to take extra notes! 


It can be purchased through Amazon, and the link is in the button below:

Click here

Example Problems from the course:

More Example Problems Can Be Found On Our YouTube Channel

CEL's YouTube Channel

Biosolids Math Problem 1- Pollutant Concentration Limit Compliance

 Laboratory analyses report that a liquid biosolids sample contains 150  mg/kg zinc on a wet mass basis. If the liquid sample were 5 percent  solids, what is the zinc concentration on a dry mass basis and is it  compliant with the Pollutant Concentration Limit (PCL or Table 3 from  Part 503 Subpart B)? 

Biosolids Math Problem 2- Site Life

Biosolids are being land applied in bulk under CPLR requirements. What is the site life (in years) if the annual pollutant loading rate for nickel (Ni) were estimated to be 19.4 kg Ni/ha and the CPLR limit (Table 2) for Ni were 420 kg/ha-year?


Copyright © 2024 Cache Environmental Laboratories - All Rights Reserved.